HK-8060 Online Luminescent Dissolved Oxygen Analyzer, a high performance online measurement instrument, is composed of transmitter and sensor. The monitor is based on fluorescence quenching to determine the oxygen content in water. Measurement signal,taking into account the water temperature and pressure, is calculated by sensor detecting and analyzing continuously. Digital communication provides fault-free communication between sensor and transmitter, which can avoid common electromagnetic noise interference in field.
Features
◆Adopt fluorescence principle which does not require frequent calibration.
◆ No drift and free maintenance.
◆There is no strict requirement for sample.
◆It has strong anti-interference ability and it is not polluted by hydrogen sulfide, heavy metals, oil and gaseous chemicals.
◆ Fast response of measurement time.
Applications
◆ Measure and control the oxygen in aeration tank during sewage treatment
◆ Monitor the water environment (river, lake, seawater .etc)
◆ Measure and control the oxygen content in public water source
◆ Measure and control the oxygen content in fishpond
◆ Measure and control the oxygen content in drinking water
◆ Power, food, chemical and other industries
Measurement Range |
(0.00~20.0)mg/L; 0-200% saturation |
|||||||||
Display |
Chinese/English, 480×272 lattice LCD |
|||||||||
Max. Resolution |
0.01 mg/L; 0.01% |
|||||||||
Display Error |
≤±0.3mg/L |
|||||||||
Repeatability |
1% |
|||||||||
Zero Drift |
±1%FS/30min |
|||||||||
Stability |
±1%FS/30min |
|||||||||
Temperature Sensor |
NTC30K |
Temp Accuracy |
±0.5℃ |
Temp Resolution |
0.1℃ |
Sample Temp |
(0~50)℃ |
|||
pH Range of Sample |
pH 2-10 |
|||||||||
Sensor Material |
316LSS |
|||||||||
Current Output |
Optional: (0~10)mA, (0~20)mA or (4~20)mA (Double channels are indeoendent isolated outputs). Double channel load: 800Ω, Error: 0.1mA |
|||||||||
Digital Output |
RS485; HART is optional. |
|||||||||
Relay Output |
Double-channel configurable |
|||||||||
Data Storage |
≥100,000 |
|||||||||
Sensor Pressure |
≤1MPa Sinkage Depth: ≤2m |
|||||||||
Response Time |
T90≤60s |
|||||||||
Power Supply |
AC (100~240)V, (50~60)Hz; Option: DC 24V |
|||||||||
Relative Humidity |
≤90% (no condensation) |
|||||||||
Storage Temperature |
(-10~60)℃ |
|||||||||
Safety Requirement |
Leakage Current |
≤3.5mA |
||||||||
Ground Resistance |
≤0.5Ω |
|||||||||
Insulation Resistance |
The insulation resistance of the power phase and the neutral wire of the electronic unit to the ground: ≥ 40MΩ |
|||||||||
Dielectric Strength |
Between the power phase, neutral wire and ground, and between the power input terminal and the metal parts that may be touched, it should be able to withstand a test voltage of AC 1500V, 50Hz for 1min, there should be no breakdown and arcing. |
|||||||||
Transmitter Overall Dimension |
146mm×146mm |
|||||||||
Sensor Overall Dimension |
302mm×155mm |
|||||||||
Sensor Cable Length |
10m |
|||||||||
Sensor Installation Mode |
Submerged installation |
|||||||||
Key |
8 keys |
|||||||||
Transmitter Mounting Mode |
Panel mounting, Wall mounting, Pipe mounting |
|||||||||
Power Consumption |
≤12W |
|||||||||
Weight |
6kg |