- Introduction
- Features
- Specifications
Total nitrogen (TN) refers to the sum of dissolved netrogen and suspended nitrogen in water, including nitrite nitrogen, nitrate nitrogen, inorganic ammonium salts, dissolved ammonia, and nitrogen jin most organic nitrogen-containing compounds.
The monitor has the functions of controlling the water sample collection automatically, high temperature digestion, reaction measurement, data processing and data transmission, which can finish the whole process of total nitrogen analysis of wastewater fast, continuously and automatically.
According to alkaline potassium persulfate UV spectrophotometric method, in the conditions of 120~124℃, the alkaline potassium persulfate solution is used as the oxidant to convert the nitrogen of nitrogen compounds in the sample into nitrates. The nitrates can react with the reagents to generate light-yellow nitro compounds, which can be measured by UV spectrophotometry.
◆ 7” LCD touch screen, displayed in Chinese or English, is easy to operate, the interface is beautiful and generous, the display content is rich and intuitive.
◆ The integrated design of digestion measurement makes the measurement result more accurate and faster.
◆ Imported monochromatic light source – Excellent performance, concentrated energy, and low power consumption.
◆ High precision injection pump – High measurement accuracy, low reagent consumption.
◆ Acid-resistant and alkali-resistant, high temperature resistant valves -- Long service life and less manual maintenance.
◆ Equipped with pretreatment device, which can meet the measurement requirements of different water quality.
◆ Auto-calibration function -- ensures more accurate measurement.
◆With intelligent maintenance function -- It can clean automatically after each detection, which ensures more accurate measurement each time and reduces the manual maintenance.
Measurement Method |
Alkaline potassium persulfate UV spectrophotometric method |
Measurement Range |
0-5mg/L; 0-20mg/L; 0-100mg/L. The range can be extended. |
Lower Limit of Detection |
0.05mg/L |
Resolution |
0.01mg/L |
Display error |
±10% |
Repeatability |
±5% |
Zero Drift |
±5%FS |
Span Drift |
±5%FS |
Measurement Interval |
1h-24h, optional |
Measurement Type |
Cyclic measurement, Fixed-point measurement, Trigger measurement |
Ambient Temperature |
5-45℃ |
Ambient Humidity |
<95% |
Display |
7” LCD touch screen |
Language |
Chinese / English |
Output |
4-20mA |
Communication |
RS485,MODBUS |
Power Supply |
AC(100-240)V; 50HZ |
Power Consumption |
<300W |
Overall Dimension |
500mm*395mm*1450mm (L*W*H) |
Weight |
About 60kg |
Other Functions |
Auto-calibration, Intelligent maintenance, Data storage, Trend curve, etc. |