- Introduction
- Features
- Specifications
In many instances, such as in the gears of a steam turbine, water can become mixed with the lubricant, and rusting of ferrous parts can occur, HK-3080XS Oils Corrosion Tester is used to indicates how well inhibited mineral oils aid in preventing this type of rusting according to GB/T 11143-2008 《Standard test method for Rust-preventing Characteristics of inhibited oil in the presence of water》, adopting stainless steel bath and intelligent PID temperature control system, Anti-corrosion and durable, which is one kind of necessary instrument for testing/analyzing petroleum products.
A mixture of 300ml of the oil under test is stirred with 30 ml of distilled water or synthetic sea water, as required, at a temperature of 60±1℃ with a cylindrical steel test rod completely immersed therein. It is recommended to run the test for 4h; however, the test period may, at the discretion of the contracting parties, be for a shorter or longer period. The test rod is observed for signs of rusting and, if desired, degree of rusting.
◆ Adopts the 800*480 LED touch screen, Chinese and English are optional. Easy- operation with the prompt menu.
◆ Adopts the PID intelligent temperature control technology, users can pre-set temperature within the temperature control range.
◆ Easily software upgrading and maintenance through the USB connector.
◆ Intelligent measure the water level, in avoid to dry heating.
◆ With the precise timing function, easy for operation.
1、 Testing hole:4
2、 Temperature control range:Room temperature~100℃
3、 Temperature measurement error :±0.5℃
4、 Temperature control accuracy :±1℃
5、 Temperature resolution:0.1℃
6、 Temperature control time:0~99h(optional)
7、 Stirring speed:1000r/min
8、 Outside dimension & Weight:L490×W403×H622mm, 65Kg.
Application Environment:
1、 Power supply:1)AC220V, 50/60HZ; AC240V, 50 HZ; 2)AC120V, 60HZ(Optional).
2、 Consumption Power:≤2650W
3、 Ambient temperature: (0~40)℃;
4、 Ambient relative humidity:≤85%RH
# The instrument should be put into a no air flow laboratory and on a stable and no glare table.
# The laboratory should have fire extinguisher and other extinguish material.
# Don’t put any inflammable、explosive and strong corrosive gas or liquid around the instrument, no strong electromagnetic interference and obvious mechanical shock.
1、Main instrument |
1 |
2、Beaker |
4 |
3、Beaker frame |
4 |
4、Beaker cover |
4 |
5、Thermometer |
1 |
6、Steel bar |
10 |
7、Stirring bar |
4 |
8、Operation manual |
1 |
9、Warranty bill |
1 |
10、QC |
1 |