- Introduction
- Features
- Specifications
Applications:
. Power. Chem or Petrochemical
. Pulp and Paper
. Semiconductor
. Ultra pure water anakysis,boiler feed waterion exchange breakthrough,steam analysis,drum boiler water
. Advanced embedded MCU technology,SMT and integrative design
. Panel mount,aluminum enclosure
---anti-interference
. 192×64 lattice LCD display
. User interface language:English
. Simultancous display of multtiparameters
. Automatic or manual temperature compensation
. Two analog outputs and two alarm relay outputs
. CAN bus communication
. Large datalog of previous measurements and trend curve trackable
. Universal power supply for worldwide operation(100~240)V
. Low reagent consumption
. Fast response,accurate measurement
---ease-of-use with minimal maintenance
TRANSMITTER |
|
Measurement Range |
(0.00 to 9.36)pNa, 0.01μg/L to 23.0g/L, (-1.000 to +1.000)mV |
Resolution (min) |
0.01pNa, 0.01ug/L, 0.1mV |
Accuracy |
0.01pNa, 1character, ±0.5mV (during ±10oC of the calibration temperature) |
Stability |
±0.01pNa/24h, ±1character/24h, ±0.5mV/24h |
Analog Output |
(0~10)mA or (0~20)mA or (4~20)mA,two isolated outputs |
Output Accuracy |
±1%F.S |
Max.load Resistance |
≤800W |
Power Supply |
(100~240)VAC, (45~65)Hz |
Power Consumption |
≤8W |
Insulation Strength |
Power to ground 1500V, no flying arc in 1 min |
Alarm Output |
Two alarm relays. Each relay can be configured as: high and low concentration alarm, high and low temperature alarm. One relay can be simultaneously selected by two alarms. If anyone of the two alarms occurs, it will be activated. |
Communication |
CAN Bus (option) |
Data Logger |
Record measurement values, history events and calibration results |
INSTRUMENT |
|
Measurement Range |
(1.00-8.00)pNa, 0.23ug/L-2300mg/L |
Resolution (min) |
0.01pNa or 0.01ug/L |
Accuracy |
±0.02pNa or ±0.5ug/L ( the larger one), whichever is greater (between ±10oC of calibration temperature) |
Response Time (T90) |
≤2 min at 25oC |
Temperature Sensor |
Pt1000 |
Temperature Range |
(0.0 to 99.9)oC |
Temperature Accuracy |
±0.5 oC |
Temperature Compensation |
(0.1 to 60.0)oC (auto or manual) |
Calibration Method |
Sample calibration and standard solution calibration |
Overall Dimension (mm) |
450(L) × 690(W) × 190(D) |
Cutout Dimensions (mm) |
410 × 645 |
Weight |
19kg |
Sample Condition |
Temperature: (5 to 50)oC Pressure: (50-300)KPa Flow: (6-40)L/h Solid contents in sample: ≤5mm (no gel and grease) |
Ambient Temperature |
(5 to 45)oC |
Ambient Humidity |
≤90%RH (no condensation) |
Storage Temperature |
(-25 to 55)oC (above 0oC for electrode) |
Warranty |
18 months(from date of acceptance) |
Analyzer
1Piece
Reactive solution
1 bottle
Measuring eletrode
1Piece
Disposable injector
1Piece
Reference electrode
1Piece
Key
1Piece
Standard solution
2 bottle